For use in Cabinets for Electronics, or other products,
that require a minimum temperature or as prevention against
humidity.
The
heater has to be used in connection with an external temperature
control.
The heater was originally constructed to heat an outdoor
mobile telephone base station.
EMC
The heater meets the following specifications
DS 5104/EN 50093
EN 55022
(Voltage dips and interruptions in supply voltage Limits
and methods of measurement of radio interference characteristics
of information technology equipment.)
Safety
The heaters are constructed to meet EN 60335-2-30.
Heaters
The heaters include a self-reset thermostat for overheating
protection.
The airflow
in the heater is 110 m3/h at DP
= 15Pa.
The
heat element has low surface temperature to improve lifetime
and minimize fire risks.
The
surface temperature of the enclosure will not exceed 80
°C under normal conditions.
The
average output temperature rise of the air is below 40K
measured 50 mm from the outlet.
Lifetime
The specified lifetime of the heaters are 175000 h corrosion
free (stand by) and 2000 h service time.
The heaters will start at -33°C.
|